Welcome to an exploration of chillers, their types, applications, and limitations. This guide aims to provide a comprehensive understanding of chillers, particularly for those involved in commercial refrigeration, such as students, apprentices, building managers, and architects. By the end of this article, you will have a clearer grasp of terms like “recip,” “turbo,” and “towers” often used by engineers.
Chillers are essential machines that produce cold or chilled water, which is then distributed throughout buildings for air conditioning. They are also used in various industrial processes. This guide will primarily focus on their application in building air conditioning.
Chillers can be categorized into two main types: vapor compression and vapor absorption chillers.
These chillers use an electrically driven mechanical compressor to circulate refrigerant throughout the system. They are the most common type and can be further divided into:
These chillers use heat instead of an electrically powered compressor to move the refrigerant around the system.
Chillers are used in buildings of varying sizes, depending on their cooling load requirements:
When selecting chillers, it’s crucial to consider the building’s criticality and required redundancy, known as the N plus number. This ensures that if one chiller fails, a backup is ready to take over. Investing in efficient chillers can lead to lower operating costs and reduced environmental emissions over time.
Different compressor technologies are available for chillers, each suited for specific applications:
This guide provides a foundational understanding of chillers, their types, and applications. By considering the specific needs of your building and the advantages and disadvantages of each chiller type, you can make informed decisions for efficient and effective cooling solutions.
Test your understanding of the different types of chillers by participating in a quiz. This activity will help you reinforce your knowledge of vapor compression and vapor absorption chillers, as well as the subcategories of water-cooled and air-cooled chillers. Challenge yourself to identify the correct chiller type based on specific scenarios and characteristics.
Engage in a case study analysis where you will evaluate the cooling needs of a hypothetical building. Determine the most suitable chiller type and compressor technology based on the building’s size, cooling load, and other requirements. Present your findings and justify your selection, considering factors like efficiency, cost, and environmental impact.
Participate in an interactive workshop where you will work in groups to select the appropriate chiller system for different building types. Discuss the pros and cons of air-cooled versus water-cooled chillers and explore the implications of various compressor technologies. This collaborative activity will enhance your decision-making skills in HVAC process engineering.
Take a virtual tour of different chiller systems used in real-world applications. Observe the components and operation of both vapor compression and vapor absorption chillers. This visual experience will help you better understand the practical aspects of chiller systems and their applications in various industries.
Engage in a group discussion focused on the energy efficiency of chiller systems. Explore strategies for optimizing chiller performance and reducing environmental emissions. Share insights on the latest advancements in chiller technology and how they contribute to sustainable building practices.
Sure! Here’s a sanitized version of the YouTube transcript:
—
Hello everyone, Paul here from TheEngineeringMindset.com. In this video, we will explore the various types of chillers, their applications, and their limitations. Before we begin, I would like to thank our partner, Danfoss, for sponsoring this video. Danfoss has been providing solutions for chillers for many years and offers a wide range of high-quality products for all chiller types. They supply up to 70% of the components needed for your chiller system, including compressors, drive system protectors, heat exchangers, valves, electronics, and sensors. These solutions help you build better chillers from the inside out. For more information, visit chillers.danfoss.com.
If you are involved in commercial refrigeration, particularly chillers, or if you are a student, apprentice, building manager, or architect, you may hear engineers using terms like “recip,” “turbo,” and “towers.” If you’re unsure what these terms mean, don’t worry; by the end of this video, you’ll have a clearer understanding.
We have previously covered how chillers work in detail, and you can find links in the video description below. If you haven’t subscribed yet, please hit the subscribe button, and we’ll help you become an expert.
To recap your previous knowledge, chillers are machines that generate cold or chilled water, which is distributed throughout buildings for air conditioning. They are also used in some industrial processes, but this video will primarily focus on their application in building air conditioning.
Chillers can be categorized in various ways, and it’s essential to understand the terminology, differences, and applications. The first way to categorize a chiller is by determining whether it is a vapor compression or a vapor absorption type. Vapor compression chillers use an electrically driven mechanical compressor to circulate refrigerant throughout the system. These are the most common type of chillers and can be further divided into water-cooled and air-cooled chillers.
Vapor absorption chillers, on the other hand, use heat to move the refrigerant around the system instead of an electrically powered compressor.
Both air-cooled and water-cooled chillers share essential components: the evaporator, compressor, condenser, and expansion valve. The distinction lies in how unwanted heat is expelled from the building via the chiller’s condenser. In air-cooled chillers, fans blow air across the condenser’s exposed tubes to carry heat away, while water-cooled chillers use a sealed condenser where water is pumped through to remove heat, often dispersing it through a cooling tower.
Where are these chillers typically used? Large buildings with cooling loads exceeding approximately 400 tons (1,400 kilowatts) usually employ water-cooled chillers, often utilizing centrifugal or turbo core type compressors within the central cooling system. They may also use a smaller air-cooled chiller for critical areas like computer and communication rooms. Additionally, an absorption chiller may be part of the central plant system, utilizing waste heat from a combined heat and power (CHP) engine, although these are generally used alongside mechanical chillers.
Medium-sized buildings with cooling loads between 200 to 400 tons (700 to 1,400 kilowatts) typically use screw or turbo core compressor chillers, which can be either water-cooled or air-cooled. Smaller buildings with cooling loads around 200 tons or less (700 kilowatts) generally use scroll or turbo core compressors, predominantly in air-cooled designs. They may also opt for different systems, such as variable refrigerant flow (VRF) units, depending on the building size and cooling load.
For medium to large cooling loads, it is advisable not to rely on a single oversized chiller for the entire cooling requirement, as this is inefficient and poses a risk of total cooling failure if it malfunctions. Instead, multiple chillers of varying sizes should be used in parallel to meet changing seasonal loads with optimal performance and built-in redundancy. For example, a building with a cooling load of 2,200 tons could utilize combinations like two 1,200 ton chillers or a mix of different sizes.
Consideration of the building’s criticality and required redundancy, known as the N plus number, is essential. The “N” represents the number of chillers needed, while the “plus” indicates the number of backup chillers required to maintain cooling capacity in case of a failure. This ensures that if one chiller fails, a backup is ready to take over.
Many building owners often seek the cheapest upfront option, which can be a poor choice. Investing a little more in a more efficient chiller can lead to lower operating costs, especially since chillers typically last 15 to 25 years or more. This investment pays off over time and contributes to reduced environmental emissions.
Now, how do you decide between an air-cooled or water-cooled chiller? This decision depends on various factors, so let’s examine the pros and cons of both.
**Pros of Water-Cooled Chillers:**
– Typically more efficient, especially for larger cooling loads.
– Utilize water evaporation to dissipate heat, which is less energy-intensive than air cooling.
– Higher heat capacity of water makes it easier to remove heat.
– Can handle larger loads relative to the floor space they occupy.
– Generally have a longer lifespan due to being housed within the building.
**Cons of Water-Cooled Chillers:**
– Require cooling towers and access to a constant supply of clean water, which may not be feasible in water-restricted areas.
– Large machines that can generate noise and vibration, often necessitating placement in basements.
– Higher installation and maintenance costs.
– Occupy space within the building that could be used for business operations.
**Pros of Air-Cooled Chillers:**
– Lower installation costs due to less equipment.
– Require less space and can be placed on rooftops or parking lots, freeing up building space.
– Generally require less maintenance compared to water-cooled chillers.
– Simpler design without the need for additional pumps for the condenser loop.
**Cons of Air-Cooled Chillers:**
– Located outside, which can lead to noise from fans and compressors that may disturb surrounding areas.
– Shorter service life due to exposure to environmental elements.
– More susceptible to blockages and damage.
Next, let’s look at some of the different compressor technologies available:
– **Centrifugal Chillers:** Used for water-cooled systems, typically for medium to large cooling loads (150 to 6,000 tons). They have a COP of around 5.8 to 7.1 and usually operate best at full load.
– **Turbo Core Compressors:** An evolution of centrifugal technology, suitable for both air and water-cooled chillers, ranging from 60 to 1,500 tons. They have a COP of 4.6 to 10 and are low maintenance.
– **Reciprocating Compressors:** Older technology used for small to medium cooling loads (50 to 500 tons) with a COP of 4.2 to 5.5.
– **Scroll Compressors:** Used for small to medium loads (40 to 400 tons), with COPs ranging from 3.2 to 4.6 for air-cooled and 4.45 to 6.2 for water-cooled.
– **Screw Compressors:** Suitable for small to medium loads (70 to 600 tons), with COPs of 2.9 to 4.15 for air-cooled and 4.7 to 6.07 for water-cooled.
– **Absorption Chillers:** Use heat to drive the refrigeration process, ideal for medium to large buildings, typically ranging from 70 to 1,400 tons, with a low COP of 0.6 to 1.9.
That wraps up our discussion. I want to thank Danfoss once again for sponsoring this video. Don’t forget to check out their extensive range of chiller solutions at chillers.danfoss.com. Thank you for watching! If you found this helpful, please like, subscribe, and share. Also, follow us on social media and visit our website, TheEngineeringMindset.com. Thanks again for watching!
—
This version maintains the informative content while removing any informal language and ensuring clarity.
Chillers – Devices used to remove heat from a liquid via a vapor-compression or absorption refrigeration cycle. – The engineers selected high-capacity chillers to ensure the building’s HVAC system could handle peak summer temperatures.
Refrigeration – The process of removing heat from a space or substance to lower its temperature and/or maintain it below the ambient temperature. – The refrigeration system in the laboratory is crucial for preserving temperature-sensitive samples.
Cooling – The process of lowering the temperature of an environment or substance, often using mechanical systems like air conditioners or chillers. – Effective cooling of the data center is essential to prevent overheating of the servers.
Compressors – Mechanical devices that increase the pressure of a gas by reducing its volume, commonly used in refrigeration and air conditioning systems. – The maintenance team regularly inspects the compressors to ensure optimal performance of the cooling system.
Absorption – A refrigeration process that uses a heat source to drive the cooling cycle, often involving a liquid absorbent and refrigerant. – Absorption chillers are often used in industrial applications where waste heat is available as an energy source.
Vapor – The gaseous phase of a substance that is normally liquid or solid at room temperature, often involved in refrigeration cycles. – The vapor compression cycle is a fundamental concept in thermodynamics and refrigeration engineering.
Air-cooled – A type of cooling system that uses air to dissipate heat from a device or process, often used in smaller or portable applications. – Air-cooled condensers are preferred in locations where water resources are limited.
Water-cooled – A cooling system that uses water to absorb and remove heat, typically more efficient than air-cooled systems for large-scale applications. – The new manufacturing plant opted for a water-cooled chiller to improve energy efficiency and reduce operational costs.
Efficiency – The ratio of useful output to total input in any system, often used to measure the performance of machines and processes. – Improving the efficiency of the HVAC system can lead to significant energy savings and reduced environmental impact.
Applications – The specific uses or purposes for which a technology or system is designed or employed. – The applications of thermodynamics extend beyond engineering, influencing fields such as chemistry and environmental science.
Cookie | Duration | Description |
---|---|---|
cookielawinfo-checkbox-analytics | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics". |
cookielawinfo-checkbox-functional | 11 months | The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". |
cookielawinfo-checkbox-necessary | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary". |
cookielawinfo-checkbox-others | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other. |
cookielawinfo-checkbox-performance | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance". |
viewed_cookie_policy | 11 months | The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data. |